mr2.algorithms.csm.espirit

mr2.algorithms.csm.espirit(coil_k_space: Tensor, img_shape: SpatialDimension[int], singular_value_threshold: float = 0.02, kernel_width: int = 6, crop_threshold: float = 0.8, n_iterations: int = 10) → Tensor[source]

Calculate a coil sensitivity map (csm) using the ESPIRIT method.

This is for a single set of Cartesian coil k-space data. The input should be a tensor with dimensions (coils, kz, ky, kx). The output has shape (coils, *img_shape.zyx). Either apply this function individually to each set of coil k-space data, or see from_kdata_espirit which performs this operation on a whole dataset [UEC2013].

This function is inspired by sigpy.mri.app.EspiritCalib.

Covariance and power iterations are evaluated in spatial slabs to limit working memory.

Parameters:
  • coil_k_space (Tensor) – Cartesian k-space for each coil element.

  • img_shape (SpatialDimension[int]) – Shape of the reconstructed image.

  • singular_value_threshold (float, default: 0.02) – Relative singular-value cutoff for calibration kernels, matching SigPy: retain s_i / s_max > singular_value_threshold. For BART ecalib -t t, use sqrt(t); BART thresholds relative calibration-Gram eigenvalues. For example, BART -t 0.02 corresponds to approximately 0.141421. The Gram eigendecomposition loses precision for very small cutoffs.

  • kernel_width (int, default: 6) – edge size of the scanning window

  • crop_threshold (float, default: 0.8) – Eigenvalue cutoff for map support, independent of the kernel cutoff. Maps with eigenvalues at or below this value are set to zero.

  • n_iterations (int, default: 10) – number of iterations in the power method

Returns:

csm of the shape (coils, z, y, x)

References

[UEC2013]

Uecker M, Lai P, Murphy MJ, Virtue P, Elad M, Pauly JM, Vasanawala SS, Lustig M (2013) ESPIRiT

  • an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA. MRM